Since patenting some of the first exit devices nearly a century ago, Corbin Russwin has met rigorous life safety and security requirements, while offering pleasing aesthetics and trouble-free operation. Designed for applications in high-use, high-abuse situations, ED6000 Crossbar Exit Devices can be teamed with a variety of Corbin Russwin trims to provide desired functions, styles and finishes in new construction.
|
|
 |
|
|
 |
Handing: Device handed but easily field reversible; specify hand.
Bar Length: Easily field cut to size. Standard: 36" (914mm) bar fits up to 36" (762mm-914mm) door. Optional: 48" (1219mm) bar fits up to 48" (1219mm) door; specify W048.
Door Thickness: 1-3/4" (44mm) standard.
Backset: 2-3/4" (70mm).
Stile: Minimum width 4-1/8" (105mm).
Door Height: All top rods easily field cut to size. Standard on ED6400 devices; top rod for doors up to 7'6". Optional on ED6400 devices; top rod for doors up to 10'
Standard on ED6400A devices; top rod for 7'2" door.
Latchbolt: ED6400 devices: Top: 5/8" throw. Bottom: 3/4" throw; acts independently, allowing top latch to remain engaged even when bottom latch is not projected.
ED6400A devices: Top: 3/4" steel, jamb mounted; projects into pusher on device. Bottom: 3/4" throw steel.
Latchbolt Operation: Standard on ED6400 and ED6400A devices: latchbolts held in retraced position until door closes.
Vertical Rods: Inverted U-shaped rectangular.
Dogging: Standard on ED6400 devices. Dogging not available on ED6400A devices.
Projection: 5-3/4" (146mm); 4-1/4" (108mm) depressed.
Fasteners: Standard on ED6400 devices: machine screws, sex nuts and bolts;
Standard on ED6400A devices; sex nuts and bolts.
Warranty: One-year limited.
Specification
Material: Brass, bronze or stainless steel.
Cases: Heavy wrought, 7-1/4" (184mm) x 2-9/16" (65mm).
Crossbar: Standard: 13/16" (1mm) x 1-3/8" (35mm) oval seamless tubing.
Certification/Compliance
ANSI: Meets A156.3, Grade 1.
C-UL US: All devices listed for safety as panic hardware; devices comply with UL 305 standards for panic hardware. 3-hour fire-rated devices listed as fire exit hardware for A label and lesser class 8' x 7'2" double doors. UL symbol on active head indicates listing.
California State Reference Code: This product has been approved by the California State Fire Marshal pursuant to section 13144.1 of the California Health and Safety Code.
NFPA: All exit devices comply with NFPA 101 Life Safety Code. All fire-rated devices comply with NFPA 80 Fire Doors and Windows.
ADA: Lever trims and pulls comply with Americans with Disabilities Act.
|
|