Product Details
RCI DKPS 2A Power Supply
IRobust applications:
Supplies eight voltage (12/24 Vdc at 2.0 amp) fail safe or fail secure outputs to support access devices including:
Electromagnetic locks, electric strikes & power bolts Specialty Electric locks Motorized Latch Retraction (MLR) Egress doors and exit devices
Ease of Maintenance :
Convenient metal housing which can accommodate up to two (2) 7 AH rechargeable batteries depending on your application Status LEDs on enclosure front door (Green, Yellow, Blue)Safety :
Supervisory outputs for remote monitoring Supervised connection to fire panel or access panel for automatic unlocking of specified doors Remote reset of power supply after fire alarm Optional front door tamper switch or dual door and wall removal tamper switches Fault and overload protection
Input & Output:
Input Voltage:110-220VAC, 50-60Hz 2.4A.
Output Voltage:Selectable 12 or 24 VDC voltage outputs; each output max 2.0 A with electronic over-current protection set at 2 Amp. 8 voltage outputs.
Dimensions:
Power Supply Board:7-11/16" x 4- 5/16" (195mm x 110mm)
Power Distribution Controller Board:7-3/8" X 3 1/2" (187mm x 90mm)
Metal Enclosure:13- 5/16" x 17- 5/8" x 4- 5/16" (338mm x 448mm x 110mm)
Weight:12 lbs (5.44 Kg).
Operating temperature:32 Degree to 120 Degree F (0 Degree to 49 Degree C).
Stand-by Battery:Application dependent. Auto switchover upon AC failure; Built in 1.5 Amp charger with current test every 48 hrs
Capacity:Enclosure supports two (2) 12VDC-7 amp-hour (AH) batteries
Type:Sealed lead acid or gel cell
Power Supply Supervision
AC Power Fail:Form C dry contact relay (Relay contacts rated 28Vdc, 300mA)
Battery:Form C dry contact relay (Relay contacts rated 28Vdc, 300mA)
Cover LED Indicators: Green: AC power; Blue: DC power; Yellow: Battery charger & fault
Power Distribution Controller - Board Supervision
DC Fail:Form C dry contact relay (Relay contacts rated 28Vdc, 300mA)
Status output:Form C dry contact relay (Relay contacts rated 28Vdc, 300mA)
Enclosure Tamper Switch:
Optional, sold separately, Normally Closed
Cover tamper part No: DKPS-TSW1-02
Cover and wall removal tamper part No: DKPS-TSW2-02
Certifications:
UL294 6th Edition Listed for access control power supply CAN/ULC-60839-11-1; CAN/ULC-S533
FCC Compliant; ISED(IC) compliant
CE compliance EMC Directive 2014/30/EU
Warranty:Limited lifetime
*Note: To maintain UL/ULC 294 Edition 6 or higher listing the optional tamper switch must be installed to an actively monitored input and cover secured with supplied hardware.