Kaba Mas 521025/521032, CDX-10 High Security Lock, Non Drill Resistant Mounting Plate, Strike Type 3

kabacdx10type3
1-Page4-MAX-x10
1-Page5-MAS-X10
kabacdx10type3
1-Page4-MAX-x10
1-Page5-MAS-X10
naxt
prev

Product Details

Kaba Mas 521025/521032, CDX-10 High Security Lock - Pedestrian Door Deadbolts, Non Drill Resistant Mounting Plate, Strike Type 3.

PRODUCT FEATURES

Power:Internal, self-powered by “Green" Rotational electromechanical PowerStar™ technology.

COMBINATIONS — 3 MODES:

- Single:1 million combinations - Dual: 500 billion combinations

- Supervisor/Subordinate:2 million combinations

- Direct Dial:No need to clear before entering combination. Once you stop turning the dial, the power will shut down after 40 seconds.

- Memory:Non-volatile

- LCD(Backlit): Limited View Backlit Liquid Crystal Display with visual controls makes dialing easy and exact.

- Combination Changes:(LCD indicator in change key mode.) Combination changed with correct combination or serial number.

- Random Number View:True Scramble

- Daylocking:NoBack Dialing:No

- Lock Reset:Automatic when bolt is thrown or 40 seconds after turning has stopped.

- Manipulation:Meets all requirements of FF-L 2740B. Resists opening through manipulation for 20 man-hours.

- Audit:The X-10 records all openings, and the record is non-resettable. The X-10 records unsuccessful attempts after 3 incorrect combination attempts and resets after a correct opening.

- Wrong Try Penalty:10-14 errors results in a 3 minute time out. 15 errors or greater results in a 4 minute time out. Both error count and penalty time resets with valid combination.

PERFORMANCE FEATURES(PER FF-L-2740B)

-Temperature:Tested -10 Degree F to 155 Degree F Operational Range.

- Salt Spray: Operational After 72 hours of continuous exposure (per UL 768 salt Spray Conversion Test).

- Cycle Test:Meets or exceeds FF-L-2740B specifications.

- Humidity:Operational after 10 days of 140 DegreeF @ 98% humidity (Operational after 10 days testing per MIL-STD-810E, Method 507.3, Procedure III, Temperature Cycling 86 Degree F to 140Degree F @ 98% RH)

- Stress:  Operational after 7 days in a stress chamber @ 194 Degree F (per UL 768 Aging Stress Distortion Test).

- Vibration: MIL-STD-810

- Shock: MIL-STD-901

- Electrical Discharge:   250KV on Dial

- Electromagnetic Pulse:   Meets FF-L-2740B specification for simulation of high altitude nuclear blast.

- Case & Bolt Strength: 600 pounds in two directions.

MOdel:Kaba Mas 521025/521032, CDX-10, 521025-521032, 521025521032, 521025 521032, 521025/521032

Kaba Mas 521025/521032, CDX-10 High Security Lock, Non Drill Resistant Mounting Plate, Strike Type 3

SKU: 521025/521032

In Stock

$2,259.44

About this item

The Kaba MAS CDX-10 (521025/521032) is a complete high-security pedestrian door deadbolt assembly consisting of the X-10 electromechanical combination lock (part 521025) mounted on a non-drill-resistant deadbolt base plate with Strike Type 3 hardware (part 521032). Strike Type 3 is configured for in-swing doors: the strike mounts on the inside wall, not into the door frame, and is the most commonly specified configuration.

 

The X-10 lock is self-powered by dormakaba's "Green" PowerStar Technology. Rotating the dial generates the power to operate the lock. No battery, no external power connection, no battery failure concern. It meets Federal Specification FF-L-2740B and is GSA (General Services Administration) approved as a Style 1 lock for use on GSA-approved Class 5 and Class 6 filing cabinets and Class 5 Security Vault Doors.

 

American Locksets is an authorized dormakaba dealer.

 

What the CDX-10 Assembly Consists Of

 

The CDX-10 (Combination Door Lock X-10) is not just the lock body. It's a complete door hardware package:

 

The X-10 lock (521025) is the electromechanical combination lock that provides the authentication and access control. The base plate (521032) is surface-mounted to the inside face of the door. The base plate serves two functions: it latches the bolt in the retracted position so the bolt cannot be inadvertently extended, and the knob on the base plate retracts the bolt for egress from the secure side.

 

The lock case includes a through-case mounting feature for simplified installation and improved protection of internal electronics. A tamper-evident security seal on the lock case provides visible confirmation if the lock has been accessed by unauthorized personnel.

 

X-10 Combination and Security Features

 

Combination capacity: Single user, 1 million combinations. Dual user, 500 billion combinations. Supervisor/Subordinate configuration, 2 million combinations.

 

Direct Dial operation: No need to clear the lock before entering the combination. Simply stop turning the dial to disengage, and the lock will automatically reset 40 seconds after dialing stops.

 

LCD display: Limited-view liquid crystal display with visual controls for easy, accurate dialing. Units manufactured after March 25, 2014 include a backlit LCD as standard, illuminating automatically with dial rotation for use in low-light or unlit storage areas. The backlit display version uses the same part numbers and carries the same GSA approval.

 

Memory: Non-volatile. Combination data is retained without power. Random number view with True Scramble prevents prediction of displayed numbers.

 

Audit trail: Records all openings with a non-re-settable record. Unsuccessful attempts are logged after three consecutive incorrect combination entries and reset after a correct opening.

 

Compliance Testing and Security Performance

 

The X-10 is the US Government's highest security standard for electromechanical locks under FF-L-2740B. Testing compliance covers:

 

Salt spray: Operational after 72 hours of continuous exposure. Humidity: Operational after 10 days at 140°F and 98% relative humidity. Thermal stress: Operational after 7 days in a stress chamber at 194°F per UL 768. Vibration: MIL-STD-810. Shock: MIL-STD-901. Electrical discharge: 250KV on dial. Electromagnetic pulse: Meets FF-L-2740B specification for high-altitude nuclear blast simulation. Case and bolt strength: 600 pounds in two directions.

 

Selecting the Right CDX-10 Configuration

 

Strike Type 3 (521032, this product): In-swing doors. Strike mounts on the inside wall. Most common specification.

 

Strike Type 2 (521031): Out-swing doors.

 

Strike Type 9 (521033): Alternate application.

 

Drill-resistant hard plate variants (521022 = Type 3, etc.) provide additional hardened steel protection against drilling attacks on the base plate. The 521032 in this listing uses a non-drill-resistant plate.

Resources

Kaba Mas 521025/521032, CDX-10 High Security Lock - Pedestrian Door Deadbolts, Non Drill Resistant Mounting Plate, Strike Type 3.

PRODUCT FEATURES

Power:Internal, self-powered by “Green" Rotational electromechanical PowerStar™ technology.

COMBINATIONS — 3 MODES:

- Single:1 million combinations - Dual: 500 billion combinations

- Supervisor/Subordinate:2 million combinations

- Direct Dial:No need to clear before entering combination. Once you stop turning the dial, the power will shut down after 40 seconds.

- Memory:Non-volatile

- LCD(Backlit): Limited View Backlit Liquid Crystal Display with visual controls makes dialing easy and exact.

- Combination Changes:(LCD indicator in change key mode.) Combination changed with correct combination or serial number.

- Random Number View:True Scramble

- Daylocking:NoBack Dialing:No

- Lock Reset:Automatic when bolt is thrown or 40 seconds after turning has stopped.

- Manipulation:Meets all requirements of FF-L 2740B. Resists opening through manipulation for 20 man-hours.

- Audit:The X-10 records all openings, and the record is non-resettable. The X-10 records unsuccessful attempts after 3 incorrect combination attempts and resets after a correct opening.

- Wrong Try Penalty:10-14 errors results in a 3 minute time out. 15 errors or greater results in a 4 minute time out. Both error count and penalty time resets with valid combination.

PERFORMANCE FEATURES(PER FF-L-2740B)

-Temperature:Tested -10 Degree F to 155 Degree F Operational Range.

- Salt Spray: Operational After 72 hours of continuous exposure (per UL 768 salt Spray Conversion Test).

- Cycle Test:Meets or exceeds FF-L-2740B specifications.

- Humidity:Operational after 10 days of 140 DegreeF @ 98% humidity (Operational after 10 days testing per MIL-STD-810E, Method 507.3, Procedure III, Temperature Cycling 86 Degree F to 140Degree F @ 98% RH)

- Stress:  Operational after 7 days in a stress chamber @ 194 Degree F (per UL 768 Aging Stress Distortion Test).

- Vibration: MIL-STD-810

- Shock: MIL-STD-901

- Electrical Discharge:   250KV on Dial

- Electromagnetic Pulse:   Meets FF-L-2740B specification for simulation of high altitude nuclear blast.

- Case & Bolt Strength: 600 pounds in two directions.

MOdel:Kaba Mas 521025/521032, CDX-10, 521025-521032, 521025521032, 521025 521032, 521025/521032

kabacdx10type3
Kaba Mas 521025/521032, CDX-10 High Security Lock, Non Drill Resistant Mounting Plate, Strike Type 3

Product code: 521025/521032

In Stock

$2,259.44

$2,259.44

kabacdx10type3
Kaba Mas 521025/521032, CDX-10 High Security Lock, Non Drill Resistant Mounting Plate, Strike Type 3

Product code: 521025/521032

In Stock

$2,259.44

$2,259.44

Kaba Mas 521025/521032, CDX-10 High Security Lock, Non Drill Resistant Mounting Plate, Strike Type 3

SKU: 521025/521032

Related products

prev
prev

Related Brands

The Kaba MAS CDX-10 (521025/521032) is a complete high-security pedestrian door deadbolt assembly consisting of the X-10 electromechanical combination lock (par

The Kaba MAS CDX-10 (521025/521032) is a complete high-security pedestrian door deadbolt assembly consisting of the X-10 electromechanical combination lock (par