Product Details
RCI ( Rutherford) DE8310-28 Electromagnetic Lock W/ Delayed Egress For Single Doors - Brushed Anodized Aluminum
Description And Features:
For single outswinging perimeter door. 10-13/16"W x 2-7/8"H x 2-1/8"D (275mm x 73mm x 54mm) – Includes 1/4" (6mm) mounting bracket Armature Plate: 7-7/16"W x 2-3/8"H x 5/8"D (190mm x 61mm x 16mm) Mode: Fail-Safe Built-in sensor detects when pressure is applied to outward swinging doors – no need to replace existing door hardware Field-selectable 15 or 30 second release delay with field-selectable 0 to 3 second nuisance delay Provision for IBC, SBC, NFPA101, UBC, BOCA or NBC of Canada compliance Unique highly visible red/green light panel indicates status of door (local) Includes 960 Keyswitch for reset and override, Building Code Sign and base unit (DE8310) includes a 914 External Sounder Dry contact SPDT and DPDT relays provided for local and/or remote monitoring Adjustable keyhole mounting Convenient plug-in wiring harnesses Easy-access wiring cavity Stabilizing 4-bolt “drop stop" mounting Surge protection Designed to overcome residual magnetism Hardened steel armature nut Includes self-drilling Teks® fasteners Includes 5/8" (16mm) armature plate Brushed Anodized Aluminum (28) finish UL 10C Auxiliary Locks Listed for fire doors rated u to 1-1/2-hour UL 294 Special Locking Arrangements Component Fire-Rated: CAN/ULC S104, UL 10C 1-1/2-Hour Strength: Up To 1,200lbf Holding Force Energy:610mA1, Auto-Sensing 12-24VDC Monitoring: Local & Remote Relay Outputs & Optional, Built-In Sounder Warranty: 5 Year Limited Warranty